- Navigation & GPS[1]
- Diagnostic Tools[6]
- Medical Consumables[1]
- Testing Equipment[2]
- Alcohol Tester[6]
- Safes[3]
- Pneumatic Tools[1]
- Contact Person : Ms. Yang Cora
- Company Name : Keyun Technology (Shenzhen) Co., Ltd.
- Tel : 86-755-26748124
- Fax : 86-755-26715360
- Address : Guangdong,Shenzhen,5th Floor, Block 8, Dayuan Ind. Zone, Pingshan 1st Rd, Taoyuan Street, Xili Town, Nanshan District
- Country/Region : China
- Zip : 518055
Related Product Searches:34C Simulator,High Quality,Simulator , Simulator for calibration
The Guth Model 34C Simulator is approved by the National Highway Traffic Safety Administration (NHTSA) and published on their Conforming Products List (CPL). Simulator has a completely adjustable solid state temperature controller eliminating broad range mercury-in-glass thermostats. Components within the wet chamber area of the simulator are rust resistant, chrome plated, or stainless steel. The all metal non-magnetic top housing is chrome plated brass, preventing rust and corrosion. This provides for uniform headspace heating and outstanding mechanical security for all fasteners. The Model 34C meets all electrical and safety standards by Underwriters Laboratories (UL) and Standards Council of Canada (CUL). The Model 34C is recommended for hospitals and clinics, conforming to these critical electrical standards. The Model 34C has a double pole power switch to eliminate shock hazard, plug-in replaceable long life neon power and heater indicator lamps. An external plug-in fuse is provided offering convenient replacement. When the sensing probe is either shorted or open, the immersion heater will be disabled. A safety ground wire is welded to this heater housing to prevent electrical shock hazard in the event an internal electrical malfunction occurs. The heater will also turn off automatically if solution is absent from the wet chamber area. The heating element will turn off when the simulator is subjected to a RF field of 10 volts/meter or greater. The simulator is provided with a high precision serialized mercury-in-glass National Institute of Standards and Technology (NIST) reference thermometer to monitor temperature of the solution. | |||||||||||||||||||||||||||||||||
PERFORMANCESolid state controller is adjustable and maintains better than ± .05°C at setpoint (34.0°C) Recovery time - less than 10.0 seconds No grommets in test chamber Warm-up time from cold start-less than 10 minutes Headspace-heated Output exhaust pipe-heated A secondary baffle is provided Laboratory Glass Container-500 ml ± 5% fill mark molded into glass MECHANICAL
ELECTRICALUL and CUL listed
TEMPERATURE MONITORNIST Mercury-in-Glass serialized reference thermometer SURE-LOK CONNECTORSMale and Female connectors prevent accidental, improper connection to breath analyzer. OPTIONS
STANDARD WARRANTY
|
34C Simulator